6.4 Inspection Method Validation (AOI/X-Ray/ICT/FCT Correlation)
Inspection is not a passive filter; it is a data acquisition system that defines the physical reality of the PCBA. Relying on unvalidated machines is arguably worse than no inspection at all, as it creates a false sense of security while satisfying neither physics nor the customer. This chapter defines the validation protocols and the critical correlation logic required to ensure your test gates—AOI, X-Ray, ICT, and FCT—actually detect the failures they are assigned to catch.
The Detection Physics (Coverage Mapping)
Do not assign a failure mode to a machine that cannot physically detect it. A camera cannot see through silicon; an electrical probe cannot measure solder fillet volume.
- AOI (Automated Optical Inspection): Line-of-Sight. Detects visible misalignment, polarity, and solder meniscus.
- Blind Spot: BGA/LGA joints, hidden solder connections.
- AXI (Automated X-Ray Inspection): Density Delta. Detects voiding, shorts, and bridging under packages.
- Blind Spot: Open circuits caused by "Head-in-Pillow" (HiP) defects where density exists but fusion does not.
- ICT (In-Circuit Test): Electrical Parametrics. Detects shorts, opens, and component values (R/L/C).
- Blind Spot: Cold solder joints that make temporary contact under probe pressure.
- FCT (Functional Test): Behavioral Logic. Validates system performance.
- Blind Spot: Latent defects (e.g., weak solder) that function now but fail under vibration.
Method Validation Protocol
Before mass production, validation must prove the machine can reject a known bad unit (Reliability) and accept a known good unit (Repeatability).
The "Golden" and "Red" Sample Test
Create a validation set comprising 1 verified "Golden Sample" (Perfect) and specific "Red Samples" (Defective) for each failure mode.
- Step 1: Run Golden Sample 30 times.
- If any False Call (False Fail) -> Then retune thresholds. Capability is low.
- Step 2: Run Red Sample (e.g., Missing Component) 10 times.
- If any Escape (False Pass) -> Then STOP. The program is invalid.
- Step 3: Introduce marginal defects (e.g., shifted component).
- If machine passes marginal unit -> Then define the specific gray zone limit in the Quality Plan.
Pro-Tip: Never use a production unit as a Golden Sample without CT-Scan or Cross-Section verification. "It passed FCT" does not mean the solder joints are structurally sound.
Correlation & Feedback Loops
Individual machines are silos. Quality exists in the correlation between them.
Scenario A: AOI Pass -> ICT Fail (Short)
Analysis: The short is likely under a component body or caused by solder paste slump bridging traces.
Action:
- If systematic -> Then Update SPI (Solder Paste Inspection) volume limits.
- If random -> Then Check pick-and-place nozzle pressure (squishing paste).
Scenario B: X-Ray Pass -> FCT Fail (BGA Open)
Analysis: Classic "Head-in-Pillow" or micro-crack. X-Ray sees the ball aligned to the pad (density match), but no metallurgical bond exists.
Action:
- If frequent -> Then Switch to 2.5D or 3D X-Ray (Laminography) to inspect the specific interface layer.
- If unavoidable -> Then Mandate Boundary Scan (JTAG) at ICT/FCT to electrically validate the net.
Scenario C: High False Call Rate (AOI)
Analysis: Engineers often loosen AOI tolerances to keep the line moving, increasing the risk of Escapes.
Action:
- If False Call rate > 5000 PPM -> Then Halt line. Re-programming required. Operators ignore alarms when false calls are high ("The Boy Who Cried Wolf" effect).
Threshold Management
Define limits based on statistical reality, not default software settings.
- Voiding (X-Ray):
- Standard: IPC-A-610 allows ≤ 25% voiding area.
- High Reliability: Set warning limit at 15%.
- If voiding > 20% in thermal pad -> Then Process Control failure (Reflow Profile).
- Component Shift (AOI):
- Limit: ≤ 50% overhang.
- Action: If shift is consistently 20% in one direction -> Then Offset pick-and-place coordinate data. Do not just widen the AOI window.
Final Checklist
Parameter | Rule / Threshold |
Validation Frequency | Run Golden/Red samples at every shift start and changeover. |
Escape Tolerance | 0. An escaped "Red Sample" invalidates the entire shift's production. |
False Call Limit | Max 3 false calls per panel. Exceeding this triggers engineering review. |
BGA Inspection | 2D X-Ray minimum; 3D X-Ray recommended for Class 3 products. |
Program Change | Any change to thresholds requires re-validation with Red Samples. |
Correlation Rule | If ICT fails, Then feed data back to AOI/SPI to close the detection gap. |
Red Sample Storage | Keep Red Samples in a locked "Defect Library" box. Do not lose them. |